October 4
AirSense 11 AutoSet
Amanda’s Account
-
Vitality
100Vitality scores AHI Leak rate Usage O2 score Vitality
Top
0.01%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.65
Decreased by 0.53
-
Oct 4th 0.65
Oct 3rd 1.18
-
Average Pressure
-
10.64
Decreased by 0.17
-
Oct 4th 10.64
Oct 3rd 10.81
-
Average Leak Rate
-
0.32
Decreased by 0.11
-
Oct 4th 0.32
Oct 3rd 0.43
-
Daily Usage
-
7h 41m
Decreased by 49m
-
Oct 4th 7h 41m
Oct 3rd 8h 30m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Hypopnea 1 0.13 20% Obstructive Apnea 4 0.52 80% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Pillows Pressure Min 9.0 cmH₂O Pressure Max 14.0 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 6 Ramp pressure 9 cmH₂O Ramp time 20.0 Mask ResMed AirFit P30i Nasal Pillows Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 8.62 10.66 12.54 13.7 Epap 5.62 7.66 9.54 10.7 Leak rate 0.0 0.0 2.4 4.8 Resp rate 6.8 15.6 18.2 20.6 Flow limit 0.0 0.0 0.02 0.18 More... Other statistics Time in apnea: 52s (0.19%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit P30i Nasal Pillows Mask (small)AHI: 1.349|Leak: 0.721|Pressure: 10.453 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage