September 26
AirCurve 11 VAuto
Hannah’s Account
-
Vitality
54.47Vitality scores AHI Leak rate Usage O2 score Vitality
Bottom
0.01%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
15.55
Increased by 4.3
-
Sep 26th 15.55
Sep 25th 11.25
-
Average Pressure
-
12.0
-
Sep 26th 12.0
Sep 25th 12.0
-
Average Leak Rate
-
37.14
Increased by 37.09
-
Sep 26th 37.14
Sep 25th 0.05
-
Daily Usage
-
4h 7m
Increased by 3h 51m
-
Sep 26th 4h 7m
Sep 25th 16m
-
-
AHI
Average for 1 night (12 sessions)
.......Events by type Event Count Per hour Share Hypopnea 7 1.70 11% Unidentified Apnea 25 6.07 40% Obstructive Apnea 2 0.49 3% Clear Airway Apnea 29 7.04 46% -
Machine Settings
AirCurve 11 VAuto
Machine settings Mode VPAP Auto Mask Full face Min EPAP 8.0 cmH₂O Max IPAP 12.0 cmH₂O PS 4.0 cmH₂O Humidity level 5 Mask ResMed AirFit N30 Nasal Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 12.0 12.0 12.0 12.0 Epap 8.0 8.0 8.0 8.0 Leak rate 0.0 30.0 105.6 120.0 Resp rate 0.0 16.4 21.4 25.8 Flow limit 0.0 0.0 0.01 0.26 More... Other statistics Time in apnea: 15m 27s (6.26%) Large leak: 2h 1m 24s (49.15%) Mask
The mask used on this date
ResMed AirFit N30 Nasal Mask (medium)AHI: 5.375|Leak: 8.430|Pressure: 13.434 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage