August 2, 2024
AirSense 10 AutoSet
Steve’s Account
-
-
Apnea Hypopnea Index
-
2.4
Increased by 0.74
-
Aug 2nd 2.4
Aug 1st 1.66
-
Average Pressure
-
9.0
-
Aug 2nd 9.0
Aug 1st 9.0
-
Average Leak Rate
-
4.6
Increased by 2.05
-
Aug 2nd 4.6
Aug 1st 2.55
-
Daily Usage
-
5h
Decreased by 26m
-
Aug 2nd 5h
Aug 1st 5h 26m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Hypopnea 1 0.20 8% Obstructive Apnea 5 1.00 42% Clear Airway Apnea 6 1.20 50% -
Machine Settings
AirSense 10 AutoSet
Machine settings Mode CPAP Mask Full face Pressure 9.0 cmH₂O EPR Off Humidity level 4 Mask No mask More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 9.0 9.0 9.0 9.0 Epap 9.0 9.0 9.0 9.0 Leak rate 0.0 3.6 15.6 16.8 Resp rate 3.4 11.2 13.8 17.8 Flow limit 0.0 0.0 0.06 0.17 More... Other statistics Time in apnea: 2m 28s (0.82%) Large leak: 8s (0.04%) Mask
The mask used on this date
No mask was set on this date
-
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2
No O2 Ring data for this night
-
O2 Ring Pulse Rate
No O2 Ring data for this night
-
O2 Ring Movement
No O2 Ring data for this night
-
Sleep Stage