August 9
AirCurve 10 ST-A
Theresa’s Account
-
Vitality
95.47Vitality scores AHI Leak rate Usage O2 score Vitality
Top
25.44%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.19
Decreased by 0.97
-
Aug 9th 0.19
Aug 8th 1.16
-
Average Pressure
-
15.43
Decreased by 1.41
-
Aug 9th 15.43
Aug 8th 16.84
-
Average Leak Rate
-
0.0
Decreased by 0.02
-
Aug 9th 0.0
Aug 8th 0.02
-
Daily Usage
-
5h 11m
Decreased by 1h 44m
-
Aug 9th 5h 11m
Aug 8th 6h 55m
-
-
AHI
Average for 1 night (3 sessions)
.......Events by type Event Count Per hour Share Hypopnea 1 0.19 100% -
Machine Settings
AirCurve 10 ST-A
Machine settings Mode iVAPS Mask Full face EPAP 9.6 cmH₂O IPAP 16.2 cmH₂O Min EPAP 5.0 cmH₂O Max EPAP 15.0 cmH₂O Min IPAP 9.4 cmH₂O Max IPAP 23.0 cmH₂O Humidity level 4 Mask ResMed AirFit F20 Full Face Mask (medium) — Keep this More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 14.0 14.9 17.6 17.6 Epap 9.6 9.6 9.6 9.6 Leak rate 0.0 0.0 0.0 0.0 Resp rate 10.0 15.2 17.4 19.8 More... Other statistics Time in apnea: 0s (0.00%) Large leak: 0s (0.00%) Time offset: 2 minutes Mask
The mask used on this date
ResMed AirFit F20 Full Face Mask (medium)Keep thisAHI: 0.927|Leak: 0.139|Pressure: 14.970 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2O2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring Pulse RateO2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring MovementO2 Ring trimmed to your CPAP session. View full ring session
-
Sleep Stage