September 11
AirSense 11 AutoSet
Matthew’s Account
-
Vitality
90.69Vitality scores AHI Leak rate Usage O2 score Vitality
Bottom
44.67%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
5.45
Decreased by 11.9
-
Sep 11th 5.45
Sep 9th 17.35
-
Average Pressure
-
7.6
-
Average Leak Rate
-
0.48
-
Daily Usage
-
8h 26m
Increased by 15m
-
Sep 11th 8h 26m
Sep 9th 8h 11m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 7 0.83 15% Obstructive Apnea 13 1.54 28% Clear Airway Apnea 26 3.08 57% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 4.0 cmH₂O Pressure Max 14.0 cmH₂O EPR Full time EPR level 3 cmH₂O Ramp pressure 4 cmH₂O Mask ResMed AirFit F30i Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 4.0 7.82 9.44 10.04 Epap 4.0 4.82 6.44 7.04 Leak rate 0.0 0.0 2.4 4.8 Resp rate 4.8 14.4 19.2 22.6 Flow limit 0.0 0.0 0.09 0.23 More... Other statistics Time in apnea: 8m 8s (1.61%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit F30i Full Face Mask (medium)AHI: 5.884|Leak: 7.801|Pressure: 9.332 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage