May 24
AirSense 11 AutoSet
Ashleigh’s Account
-
Vitality
99.59Vitality scores AHI Leak rate Usage O2 score Vitality
Top
1.97%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.11
Increased by 0.52
-
May 24th 1.11
May 23rd 0.59
-
Average Pressure
-
9.14
Decreased by 0.17
-
May 24th 9.14
May 23rd 9.31
-
Average Leak Rate
-
0.26
Increased by 0.25
-
May 24th 0.26
May 23rd 0.01
-
Daily Usage
-
9h 55m
Decreased by 11m
-
May 24th 9h 55m
May 23rd 10h 6m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Clear Airway Apnea 11 1.11 100% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 9.0 cmH₂O Pressure Max 13.0 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 5 Ramp pressure 8 cmH₂O Mask ResMed AirFit F40 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 8.0 9.08 9.64 9.9 Epap 5.0 6.08 6.64 6.9 Leak rate 0.0 0.0 1.2 10.8 Resp rate 6.4 16.8 19.2 22.6 Flow limit 0.0 0.0 0.0 0.06 More... Other statistics Time in apnea: 2m 33s (0.43%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit F40 Full Face Mask (medium)AHI: 0.652|Leak: 0.263|Pressure: 9.052 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage