April 27
AirSense 11 AutoSet
Ashleigh’s Account
-
Vitality
99.84Vitality scores AHI Leak rate Usage O2 score Vitality
Top
0.78%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.07
Increased by 0.04
-
Apr 27th 1.07
Apr 26th 1.03
-
Average Pressure
-
8.16
Decreased by 0.26
-
Apr 27th 8.16
Apr 26th 8.42
-
Average Leak Rate
-
0.03
Increased by 0.02
-
Apr 27th 0.03
Apr 26th 0.01
-
Daily Usage
-
8h 25m
Increased by 1h 38m
-
Apr 27th 8h 25m
Apr 26th 6h 47m
-
-
AHI
Average for 1 night (4 sessions)
.......Events by type Event Count Per hour Share Clear Airway Apnea 9 1.07 100% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 8.0 cmH₂O Pressure Max 13.0 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 5 Mask ResMed AirFit F40 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 8.0 8.08 8.48 9.08 Epap 5.0 5.08 5.48 6.08 Leak rate 0.0 0.0 0.0 0.0 Resp rate 7.6 16.0 20.2 25.0 Flow limit 0.0 0.0 0.0 0.08 More... Other statistics Time in apnea: 1m 40s (0.33%) Large leak: 9s (0.03%) Mask
The mask used on this date
ResMed AirFit F40 Full Face Mask (medium)AHI: 0.652|Leak: 0.263|Pressure: 9.052 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2
No O2 Ring data for this night
-
O2 Ring Pulse Rate
No O2 Ring data for this night
-
O2 Ring Movement
No O2 Ring data for this night
-
Sleep Stage