Join the fun! Create a free account or sign in

Labor Day Special!

To celebrate Labor Day, get a year of SleepHQ Pro for only $119 USD (normally $149 USD).

Offer ends in 3 days.

Data recorded in New Delhi (GMT+05:30) time

Vitality

89.87
AHI
99.52
Leak rate
99.96
Usage
60.49
O2 score
N/A

Vitality

Bottom

39.92%

of all users

AHI
Top 2.14% of all users
Leak rate
Top 0.22% of all users
Usage
6.17%
O2 score
N/A

Apnea Hypopnea Index

1.1

Increased by 0.1

Average Pressure

12.0

Increased by 1.0

Average Leak Rate

2.22

Decreased by 0.94

Daily Usage

3h 38m

Increased by 38m

    AHI

    Average for 1 night (2 sessions)

    .......

    Machine Settings

    S9 Lumis VPAP 100 ST

    Mode BiLevel-S
    Mask Nasal
    EPAP 7.0 cmH₂O
    IPAP 12.0 cmH₂O
    PS 5.0 cmH₂O
    Mask ResMed AirFit N30 Nasal Mask (medium)
    More...

    Statistics

    Usage Statistics

    Min Med 95% 99.5%
    Pressure 12.0 12.0 12.0 12.0
    Epap 7.0 7.0 7.0 7.0
    Leak rate 0.0 0.0 20.4 21.6
    Resp rate 7.8 15.0 17.8 22.2
    More...
    Time in apnea: 0s (0.00%)
    Large leak: 6s (0.05% )

    Mask

    The mask used on this date

    ResMed AirFit N30 Nasal Mask (medium)
    AHI: 1.726
    |
    Leak: 1.969
    |
    Pressure: 10.473
    Pressure
    Breathing
    Leak Rate
    Flow Limit
    Snore
    SpO2
    Pulse Rate
    Movement
    Sleep Stage