January 10
AirSense 11 AutoSet
Robert ’s Account
-
Vitality
94.21Vitality scores AHI Leak rate Usage O2 score Vitality
Top
33.39%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
3.6
Decreased by 5.38
-
Jan 10th 3.6
Jan 9th 8.98
-
Average Pressure
-
11.14
Increased by 0.13
-
Jan 10th 11.14
Jan 9th 11.01
-
Average Leak Rate
-
2.98
Decreased by 1.4
-
Jan 10th 2.98
Jan 9th 4.38
-
Daily Usage
-
7h 30m
Increased by 9m
-
Jan 10th 7h 30m
Jan 9th 7h 21m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 1 0.13 4% Obstructive Apnea 14 1.87 52% Clear Airway Apnea 12 1.60 44% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 10.0 cmH₂O Pressure Max 13.6 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 1 Mask ResMed AirFit F40 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 10.0 10.88 13.34 13.58 Epap 7.0 7.88 10.34 10.58 Leak rate 0.0 0.0 18.0 27.6 Resp rate 0.0 13.2 14.8 18.2 Flow limit 0.0 0.0 0.14 0.26 More... Other statistics Time in apnea: 7m 47s (1.73%) Large leak: 3m 44s (0.83%) Mask
The mask used on this date
ResMed AirFit F40 Full Face Mask (medium)Purchased:about 1 year agoAHI: 2.678|Leak: 4.900|Pressure: 12.539 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage