December 9, 2025
AirSense 11 AutoSet
Robert ’s Account
-
Vitality
94.48Vitality scores AHI Leak rate Usage O2 score Vitality
Top
31.69%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.56
Decreased by 1.35
-
Dec 9th 2.56
Dec 8th 3.91
-
Average Pressure
-
11.32
Increased by 0.18
-
Dec 9th 11.32
Dec 8th 11.14
-
Average Leak Rate
-
9.88
Decreased by 9.43
-
Dec 9th 9.88
Dec 8th 19.31
-
Daily Usage
-
7h 25m
-
Dec 9th 7h 25m
Dec 8th 7h 25m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 1 0.13 5% Unidentified Apnea 1 0.13 5% Obstructive Apnea 8 1.08 42% Clear Airway Apnea 9 1.21 47% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Pillows Pressure Min 10.0 cmH₂O Pressure Max 14.4 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 1 Mask ResMed AirFit F40 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 10.0 11.1 13.6 14.38 Epap 7.0 8.1 10.6 11.38 Leak rate 0.0 7.2 31.2 37.2 Resp rate 0.0 13.2 15.2 19.6 Flow limit 0.0 0.0 0.08 0.32 More... Other statistics Time in apnea: 6m 3s (1.36%) Large leak: 57m 14s (12.86%) Mask
The mask used on this date
ResMed AirFit F40 Full Face Mask (medium)Purchased:about 1 year agoAHI: 2.678|Leak: 4.900|Pressure: 12.539 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage