March 2
AirSense 10 AutoSet
James’ Account
-
Vitality
95.23Vitality scores AHI Leak rate Usage O2 score Vitality
Top
26.97%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.79
Increased by 1.21
-
Mar 2nd 2.79
Mar 1st 1.58
-
Average Pressure
-
10.89
Increased by 0.06
-
Mar 2nd 10.89
Mar 1st 10.83
-
Average Leak Rate
-
4.23
Increased by 3.28
-
Mar 2nd 4.23
Mar 1st 0.95
-
Daily Usage
-
6h 27m
Decreased by 31m
-
Mar 2nd 6h 27m
Mar 1st 6h 58m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 4 0.62 22% Unidentified Apnea 2 0.31 11% Obstructive Apnea 7 1.09 39% Clear Airway Apnea 5 0.78 28% -
Machine Settings
AirSense 10 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 9.0 cmH₂O Pressure Max 12.6 cmH₂O EPR Off Humidity level 4 Mask ResMed AirTouch F20 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 9.0 10.8 12.46 12.6 Epap 9.0 10.8 12.46 12.6 Leak rate 0.0 1.2 27.6 60.0 Resp rate 6.4 15.0 24.0 42.0 Flow limit 0.0 0.0 0.13 0.35 More... Other statistics Time in apnea: 3m 4s (0.79%) Large leak: 20m 46s (5.37%) Mask
The mask used on this date
ResMed AirTouch F20 Full Face Mask (medium)AHI: 2.849|Leak: 1.788|Pressure: 10.640 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2O2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring Pulse RateO2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring MovementO2 Ring trimmed to your CPAP session. View full ring session
-
Sleep Stage