August 17, 2025
AirSense 10 AutoSet
James’ Account
-
Vitality
94.86Vitality scores AHI Leak rate Usage O2 score Vitality
Top
29.26%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.89
Decreased by 0.86
-
Aug 17th 1.89
Aug 16th 2.75
-
Average Pressure
-
10.55
Increased by 0.06
-
Aug 17th 10.55
Aug 16th 10.49
-
Average Leak Rate
-
0.68
Decreased by 0.6
-
Aug 17th 0.68
Aug 16th 1.28
-
Daily Usage
-
5h 49m
Decreased by 1h 5m
-
Aug 17th 5h 49m
Aug 16th 6h 54m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 2 0.34 18% Obstructive Apnea 1 0.17 9% Clear Airway Apnea 8 1.38 73% -
Machine Settings
AirSense 10 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 9.0 cmH₂O Pressure Max 12.6 cmH₂O EPR Off Humidity level 4 Mask ResMed AirTouch F20 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 9.0 10.22 12.54 12.6 Epap 9.0 10.22 12.54 12.6 Leak rate 0.0 0.0 3.6 4.8 Resp rate 9.2 16.0 27.4 45.8 Flow limit 0.0 0.0 0.15 0.36 More... Other statistics Time in apnea: 2m 8s (0.61%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirTouch F20 Full Face Mask (medium)AHI: 2.849|Leak: 1.788|Pressure: 10.640 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2
No O2 Ring data for this night
-
O2 Ring Pulse Rate
No O2 Ring data for this night
-
O2 Ring Movement
No O2 Ring data for this night
-
Sleep Stage