September 16
AirSense 11 AutoSet
Michael’s Account
-
Vitality
96.34Vitality scores AHI Leak rate Usage O2 score Vitality
Top
20.08%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.63
Decreased by 0.03
-
Sep 16th 1.63
Sep 15th 1.66
-
Average Pressure
-
18.84
Decreased by 0.4
-
Sep 16th 18.84
Sep 15th 19.24
-
Average Leak Rate
-
10.41
Increased by 8.69
-
Sep 16th 10.41
Sep 15th 1.72
-
Daily Usage
-
7h 58m
Decreased by 27m
-
Sep 16th 7h 58m
Sep 15th 8h 25m
-
-
AHI
Average for 1 night (4 sessions)
.......Events by type Event Count Per hour Share Hypopnea 2 0.25 15% Unidentified Apnea 1 0.13 8% Obstructive Apnea 10 1.26 77% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 17.6 cmH₂O Pressure Max 20.0 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 7 Mask Fisher and Paykel Evora Full Face Mask (extra small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 17.6 18.82 19.98 20.0 Epap 14.6 15.82 16.98 17.0 Leak rate 0.0 2.4 34.8 50.4 Resp rate 6.6 15.2 20.0 26.0 Flow limit 0.0 0.0 0.13 0.51 More... Other statistics Time in apnea: 2m 6s (0.44%) Large leak: 1h 29m 38s (18.75%) Mask
The mask used on this date
Fisher and Paykel Evora Full Face Mask (extra small)Purchased:6 months agoAHI: 5.618|Leak: 2.728|Pressure: 18.857 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage