September 29, 2025
AirSense 11 AutoSet
Israel’s Account
-
Vitality
92.17Vitality scores AHI Leak rate Usage O2 score Vitality
Top
46.34%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
4.01
Decreased by 3.58
-
Sep 29th 4.01
Sep 28th 7.59
-
Average Pressure
-
11.18
Decreased by 0.69
-
Sep 29th 11.18
Sep 28th 11.87
-
Average Leak Rate
-
0.08
Decreased by 0.72
-
Sep 29th 0.08
Sep 28th 0.8
-
Daily Usage
-
6h 29m
Increased by 57m
-
Sep 29th 6h 29m
Sep 28th 5h 32m
-
-
AHI
Average for 1 night (3 sessions)
.......Events by type Event Count Per hour Share Hypopnea 12 1.85 46% Obstructive Apnea 6 0.93 23% Clear Airway Apnea 8 1.23 31% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 10.0 cmH₂O Pressure Max 15.0 cmH₂O EPR Full time EPR level 3 cmH₂O Ramp pressure 4 cmH₂O Ramp time 5.0 Mask ResMed AirTouch F20 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 4.44 10.84 14.1 15.0 Epap 4.0 7.84 11.1 12.0 Leak rate 0.0 0.0 0.0 4.8 Resp rate 2.4 14.2 17.4 26.0 Flow limit 0.0 0.0 0.07 0.42 More... Other statistics Time in apnea: 4m 29s (1.15%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirTouch F20 Full Face Mask (medium)Purchased:about 1 year agoAHI: 5.046|Leak: 0.359|Pressure: 11.983 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage