May 31, 2025
AirCurve 10 ASV
Noah’s
-
-
Apnea Hypopnea Index
-
0.44
Decreased by 0.11
-
May 31st 0.44
May 30th 0.55
-
Average Pressure
-
NA
-
Average Leak Rate
-
NA
-
Daily Usage
-
13h 41m
Increased by 56m
-
May 31st 13h 41m
May 30th 12h 45m
-
-
AHI
Average for 1 night (6 sessions)
.......No event breakdown available
-
Machine Settings
AirCurve 10 ASV
Machine settings Mode ASV Auto Mask Full face Min EPAP 5.0 cmH₂O Max EPAP 15.0 cmH₂O Min IPAP 5.0 cmH₂O Max IPAP 28.0 cmH₂O Humidity level 4 Mask ResMed AirFit F20 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 0.0 0.0 0.0 0.0 Epap 0.0 0.0 0.0 0.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 0.0 0.0 0.0 0.0 Flow limit 0.0 0.0 0.0 0.0 More... Other statistics Time in apnea: 0s (0.00%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit F20 Full Face Mask (medium)Purchased:about 1 year agoAHI: 1.273|Leak: 30.644|Pressure: 9.234 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2
No O2 Ring data for this night
-
O2 Ring Pulse Rate
No O2 Ring data for this night
-
O2 Ring Movement
No O2 Ring data for this night
-
Sleep Stage