Join the fun! Create a free account or sign in

Data recorded in Berlin (GMT+01:00) time

Vitality

92.52
AHI
100
Leak rate
70.08
Usage
100
O2 score
N/A

Vitality

Top

44.15%

of all users

AHI
Top 0.01% of all users
Leak rate
1.02%
Usage
Top 0.01% of all users
O2 score
N/A

Apnea Hypopnea Index

0.11

Increased by 0.01

Average Pressure

7.26

Increased by 0.19

Average Leak Rate

22.87

Decreased by 5.25

Daily Usage

9h 31m

by

    AHI

    Average for 1 night (6 sessions)

    .......

    Machine Settings

    AirSense11AutoSet

    Mode APAP
    Mask Pillows
    Pressure Min 8.0 cmH₂O
    Pressure Max 12.0 cmH₂O
    EPR Full time
    EPR level 2 cmH₂O
    Humidity level 1
    Ramp pressure 4 cmH₂O
    Ramp time 45.0
    Mask Air Liquide Respireo
    More...

    Statistics

    Usage Statistics

    Min Med 95% 99.5%
    Pressure 4.02 8.0 8.48 8.98
    Epap 4.0 6.0 6.48 6.98
    Leak rate 0.0 21.6 51.6 72.0
    Resp rate 11.8 19.6 24.0 28.4
    Flow limit 0.0 0.0 0.02 0.1
    More...
    Time in apnea: 0s (0.00%)
    Large leak: 4h 22m 5s (45.90% )

    Mask

    The mask used on this date

    Air Liquide Respireo Nina Nasal CPAP Mask (medium)
    Purchased:
    5 months ago
    AHI: 0.336
    |
    Leak: 22.942
    |
    Pressure: 6.569
    Pressure
    Breathing
    Leak Rate
    Flow Limit
    Snore
    SpO2
    Pulse Rate
    Movement
    Sleep Stage