February 16
AirCurve11VAuto
Chris’ Account
-
Vitality
99.63Vitality scores AHI Leak rate Usage O2 score Vitality
Top
1.78%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.09
Decreased by 0.4
-
Feb 16th 1.09
Feb 15th 1.49
-
Average Pressure
-
12.03
Increased by 0.01
-
Feb 16th 12.03
Feb 15th 12.02
-
Average Leak Rate
-
0.0
-
Feb 16th 0.0
Feb 15th 0.0
-
Daily Usage
-
9h 11m
Increased by 2h 27m
-
Feb 16th 9h 11m
Feb 15th 6h 44m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Hypopnea 3 0.33 30% Obstructive Apnea 7 0.76 70% -
Machine Settings
AirCurve11VAuto
Machine settings Mode VPAP Auto Mask Pillows Min EPAP 8.4 cmH₂O Max IPAP 12.2 cmH₂O PS 3.4 cmH₂O Humidity level 2 Mask Fisher and Paykel Nova Micro Nasal Pillow Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 11.8 12.04 12.18 12.2 Epap 8.4 8.64 8.78 8.8 Leak rate 0.0 0.0 0.0 0.0 Resp rate 7.0 14.2 16.8 20.4 Flow limit 0.0 0.0 0.0 0.18 More... Other statistics Time in apnea: 1m 13s (0.22%) Large leak: 0s (0.00%) Time offset: -5 seconds Mask
The mask used on this date
Fisher and Paykel Nova Micro Nasal Pillow Mask (small)Purchased:over 1 year agoAHI: 0.940|Leak: 0.013|Pressure: 11.474 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2O2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring Pulse RateO2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring MovementO2 Ring trimmed to your CPAP session. View full ring session
-
Sleep Stage