September 28
S9 Lumis VPAP 150 ST-A
Darren.Allison1977
-
Vitality
97.34Vitality scores AHI Leak rate Usage O2 score Vitality
Top
14.15%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.17
Increased by 0.32
-
Sep 28th 2.17
Sep 27th 1.85
-
Average Pressure
-
12.2
-
Sep 28th 12.2
Sep 27th 12.2
-
Average Leak Rate
-
0.0
Decreased by 0.01
-
Sep 28th 0.0
Sep 27th 0.01
-
Daily Usage
-
8h 17m
Increased by 1h 15m
-
Sep 28th 8h 17m
Sep 27th 7h 2m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 10 1.21 56% Unidentified Apnea 8 0.97 44% -
Machine Settings
S9 Lumis VPAP 150 ST-A
Machine settings Mode BiLevel-S Mask Pillows EPAP 8.0 cmH₂O IPAP 12.2 cmH₂O PS 4.2 cmH₂O Humidity level 5 Mask ResMed AirFit™ P10 Nasal Pillow Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 12.2 12.2 12.2 12.2 Epap 8.0 8.0 8.0 8.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 4.8 10.8 15.2 19.2 More... Other statistics Time in apnea: 1m 32s (0.31%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit™ P10 Nasal Pillow Mask (small)Purchased:over 1 year agoAHI: 1.435|Leak: 1.648|Pressure: 13.168 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage