September 26
S9 Lumis VPAP 150 ST-A
Darren.Allison1977
-
Vitality
100Vitality scores AHI Leak rate Usage O2 score Vitality
Top
0.01%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.96
Decreased by 2.66
-
Sep 26th 0.96
Sep 25th 3.62
-
Average Pressure
-
12.2
-
Sep 26th 12.2
Sep 25th 12.2
-
Average Leak Rate
-
0.15
Decreased by 0.17
-
Sep 26th 0.15
Sep 25th 0.32
-
Daily Usage
-
7h 16m
Decreased by 2h 7m
-
Sep 26th 7h 16m
Sep 25th 9h 23m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 2 0.28 29% Unidentified Apnea 5 0.69 71% -
Machine Settings
S9 Lumis VPAP 150 ST-A
Machine settings Mode BiLevel-S Mask Pillows EPAP 8.0 cmH₂O IPAP 12.2 cmH₂O PS 4.2 cmH₂O Humidity level 5 Mask ResMed AirFit™ P10 Nasal Pillow Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 12.2 12.2 12.2 12.2 Epap 8.0 8.0 8.0 8.0 Leak rate 0.0 0.0 1.2 3.6 Resp rate 6.0 11.6 17.2 22.4 More... Other statistics Time in apnea: 55s (0.21%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit™ P10 Nasal Pillow Mask (small)Purchased:over 1 year agoAHI: 1.435|Leak: 1.648|Pressure: 13.168 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage