July 5
S9 Lumis VPAP 150 ST-A
Darren.Allison1977
-
Vitality
96.93Vitality scores AHI Leak rate Usage O2 score Vitality
Top
16.54%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.3
Increased by 1.42
-
Jul 5th 2.3
Jul 4th 0.88
-
Average Pressure
-
12.0
-
Jul 5th 12.0
Jul 4th 12.0
-
Average Leak Rate
-
0.18
Increased by 0.05
-
Jul 5th 0.18
Jul 4th 0.13
-
Daily Usage
-
6h 57m
Increased by 10m
-
Jul 5th 6h 57m
Jul 4th 6h 47m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Hypopnea 9 1.29 56% Unidentified Apnea 7 1.01 44% -
Machine Settings
S9 Lumis VPAP 150 ST-A
Machine settings Mode BiLevel-S Mask Pillows EPAP 8.0 cmH₂O IPAP 12.0 cmH₂O PS 4.0 cmH₂O Humidity level 4 Mask ResMed AirFit™ P10 Nasal Pillow Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 12.0 12.0 12.0 12.0 Epap 8.0 8.0 8.0 8.0 Leak rate 0.0 0.0 1.2 6.0 Resp rate 5.6 12.0 15.0 19.2 More... Other statistics Time in apnea: 1m 27s (0.35%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit™ P10 Nasal Pillow Mask (small)Purchased:over 1 year agoAHI: 1.435|Leak: 1.648|Pressure: 13.168 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage