February 20
S9 Lumis VPAP 150 ST-A
Darren.Allison1977
-
Vitality
99.29Vitality scores AHI Leak rate Usage O2 score Vitality
Top
3.48%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.74
Decreased by 0.48
-
Feb 20th 0.74
Feb 19th 1.22
-
Average Pressure
-
13.0
-
Feb 20th 13.0
Feb 19th 13.0
-
Average Leak Rate
-
0.01
Decreased by 1.09
-
Feb 20th 0.01
Feb 19th 1.1
-
Daily Usage
-
6h 43m
Decreased by 1h 30m
-
Feb 20th 6h 43m
Feb 19th 8h 13m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 2 0.30 40% Unidentified Apnea 3 0.45 60% -
Machine Settings
S9 Lumis VPAP 150 ST-A
Machine settings Mode BiLevel-S Mask Pillows EPAP 9.0 cmH₂O IPAP 13.0 cmH₂O PS 4.0 cmH₂O Humidity level 4 Mask ResMed AirFit™ P10 Nasal Pillow Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 13.0 13.0 13.0 13.0 Epap 9.0 9.0 9.0 9.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 6.4 13.0 17.8 22.6 More... Other statistics Time in apnea: 37s (0.15%) Large leak: 2s (0.01%) Mask
The mask used on this date
ResMed AirFit™ P10 Nasal Pillow Mask (small)Purchased:over 1 year agoAHI: 1.435|Leak: 1.648|Pressure: 13.168 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage