March 4
AirCurve 10 VAuto
James’ Account
-
Vitality
95.38Vitality scores AHI Leak rate Usage O2 score Vitality
Top
26.02%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.06
Decreased by 1.64
-
Mar 4th 2.06
Mar 3rd 3.7
-
Average Pressure
-
16.23
Decreased by 0.08
-
Mar 4th 16.23
Mar 3rd 16.31
-
Average Leak Rate
-
10.42
Decreased by 1.89
-
Mar 4th 10.42
Mar 3rd 12.31
-
Daily Usage
-
7h 46m
Increased by 12m
-
Mar 4th 7h 46m
Mar 3rd 7h 34m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Hypopnea 2 0.26 13% Obstructive Apnea 3 0.39 19% Clear Airway Apnea 11 1.42 69% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Nasal Min EPAP 12.0 cmH₂O Max IPAP 17.0 cmH₂O PS 4.0 cmH₂O Mask Philips Respironics DreamWear Nasal Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 16.0 16.2 16.68 16.94 Epap 12.0 12.2 12.68 12.94 Leak rate 0.0 6.0 32.4 45.6 Resp rate 2.4 10.6 16.0 22.0 Flow limit 0.0 0.0 0.0 0.19 More... Other statistics Time in apnea: 3m 7s (0.67%) Large leak: 43m 46s (9.39%) Mask
The mask used on this date
Philips Respironics DreamWear Nasal Mask (small)AHI: 2.522|Leak: 3.474|Pressure: 13.822 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage