February 12
AirCurve 10 VAuto
James’ Account
-
Vitality
90.61Vitality scores AHI Leak rate Usage O2 score Vitality
Bottom
44.16%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
4.94
Increased by 2.78
-
Feb 12th 4.94
Feb 11th 2.16
-
Average Pressure
-
17.0
-
Feb 12th 17.0
Feb 11th 17.0
-
Average Leak Rate
-
7.02
Decreased by 2.15
-
Feb 12th 7.02
Feb 11th 9.17
-
Daily Usage
-
7h 17m
Decreased by 1h 2m
-
Feb 12th 7h 17m
Feb 11th 8h 19m
-
-
AHI
Average for 1 night (4 sessions)
.......Events by type Event Count Per hour Share Hypopnea 1 0.14 3% Unidentified Apnea 1 0.14 3% Obstructive Apnea 3 0.41 8% Clear Airway Apnea 31 4.26 86% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Nasal Min EPAP 13.0 cmH₂O Max IPAP 17.0 cmH₂O PS 4.0 cmH₂O Mask Philips Respironics DreamWear Nasal Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 17.0 17.0 17.0 17.0 Epap 13.0 13.0 13.0 13.0 Leak rate 0.0 4.8 16.8 34.8 Resp rate 2.4 10.4 14.6 23.8 Flow limit 0.0 0.0 0.0 0.22 More... Other statistics Time in apnea: 7m 26s (1.70%) Large leak: 6m 18s (1.44%) Mask
The mask used on this date
Philips Respironics DreamWear Nasal Mask (small)AHI: 2.522|Leak: 3.474|Pressure: 13.822 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage