January 1
AirCurve 10 VAuto
James’ Account
-
Vitality
94.84Vitality scores AHI Leak rate Usage O2 score Vitality
Top
29.39%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
3.34
Increased by 2.59
-
Jan 1st 3.34
Dec 31st 0.75
-
Average Pressure
-
17.0
-
Jan 1st 17.0
Dec 31st 17.0
-
Average Leak Rate
-
0.8
Decreased by 1.19
-
Jan 1st 0.8
Dec 31st 1.99
-
Daily Usage
-
7h 47m
Increased by 1h 7m
-
Jan 1st 7h 47m
Dec 31st 6h 40m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Hypopnea 1 0.13 4% Obstructive Apnea 3 0.39 12% Clear Airway Apnea 22 2.83 85% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Nasal Min EPAP 13.0 cmH₂O Max IPAP 17.0 cmH₂O PS 4.0 cmH₂O Mask Philips Respironics DreamWear Nasal Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 17.0 17.0 17.0 17.0 Epap 13.0 13.0 13.0 13.0 Leak rate 0.0 0.0 4.8 18.0 Resp rate 3.8 11.6 16.4 22.6 Flow limit 0.0 0.0 0.0 0.21 More... Other statistics Time in apnea: 4m 52s (1.04%) Large leak: 1m 42s (0.36%) Mask
The mask used on this date
Philips Respironics DreamWear Nasal Mask (small)AHI: 2.522|Leak: 3.474|Pressure: 13.822 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage