Join the fun! Create a free account or sign in

Data recorded in Sydney (GMT+11:00) time

Vitality

72.22
AHI
71.96
Leak rate
99.98
Usage
44.98
O2 score
N/A

Vitality

Bottom

0.46%

of all users

AHI
2.83%
Leak rate
Top 0.11% of all users
Usage
0.69%
O2 score
N/A

Apnea Hypopnea Index

8.18

Decreased by 12.79

Average Pressure

11.41

Increased by 1.0

Average Leak Rate

2.14

Decreased by 10.43

Daily Usage

2h 34m

by

    AHI

    Average for 1 night (4 sessions)

    .......

    Machine Settings

    DreamStation Auto CPAP

    Mode CPAP
    Pressure 10.5 cmH₂O
    Mask Fisher and Paykel
    More...

    Statistics

    Usage Statistics

    Min Med 95% 99.5%
    Pressure 9.0 12.0 12.0 12.0
    Epap 7.5 11.1 11.4 11.5
    Leak rate 0.0 1.0 7.0 7.0
    Resp rate 5.2 13.0 20.2 23.6
    Flow limit 0.0 0.0 0.0 0.0
    More...
    Time in apnea: 0s (0.00%)
    Large leak: 47s (0.51% )

    Mask

    The mask used on this date

    Fisher and Paykel Evora Full Face Mask (large)
    Purchased:
    12 months ago
    AHI: 6.683
    |
    Leak: 13.036
    |
    Pressure: 11.769
    Pressure
    Breathing
    Leak Rate
    Flow Limit
    Snore
    SpO2
    Pulse Rate
    Movement
    Sleep Stage