September 14
AirSense 11 AutoSet
Mary’s Account
-
Vitality
96.23Vitality scores AHI Leak rate Usage O2 score Vitality
Top
20.74%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.68
Increased by 0.42
-
Sep 14th 2.68
Sep 13th 2.26
-
Average Pressure
-
10.82
Increased by 0.42
-
Sep 14th 10.82
Sep 13th 10.4
-
Average Leak Rate
-
0.4
Decreased by 0.16
-
Sep 14th 0.4
Sep 13th 0.56
-
Daily Usage
-
8h 57m
Increased by 1h 25m
-
Sep 14th 8h 57m
Sep 13th 7h 32m
-
-
AHI
Average for 1 night (7 sessions)
.......Events by type Event Count Per hour Share Obstructive Apnea 4 0.45 17% Clear Airway Apnea 20 2.23 83% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode Auto for her Mask Full face Pressure Min 10.2 cmH₂O Pressure Max 11.8 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 4 Mask ResMed AirTouch F20 Full Face Mask (large) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 10.2 10.74 11.66 11.8 Epap 7.2 7.74 8.66 8.8 Leak rate 0.0 0.0 2.4 7.2 Resp rate 4.6 17.2 22.8 28.0 Flow limit 0.0 0.0 0.0 0.14 More... Other statistics Time in apnea: 5m 38s (1.05%) Large leak: 8s (0.02%) Mask
The mask used on this date
ResMed AirTouch F20 Full Face Mask (large)AHI: 2.930|Leak: 2.073|Pressure: 8.892 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage