August 12
AirSense 11 AutoSet
Mary’s Account
-
Vitality
96.91Vitality scores AHI Leak rate Usage O2 score Vitality
Top
16.67%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.27
Decreased by 1.21
-
Aug 12th 2.27
Aug 11th 3.48
-
Average Pressure
-
8.0
-
Aug 12th 8.0
Aug 11th 8.0
-
Average Leak Rate
-
3.68
Decreased by 0.07
-
Aug 12th 3.68
Aug 11th 3.75
-
Daily Usage
-
8h 48m
Increased by 1h 20m
-
Aug 12th 8h 48m
Aug 11th 7h 28m
-
-
AHI
Average for 1 night (3 sessions)
.......Events by type Event Count Per hour Share Hypopnea 10 1.14 50% Obstructive Apnea 4 0.45 20% Clear Airway Apnea 6 0.68 30% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode CPAP Mask Full face Pressure 8.0 cmH₂O EPR Ramp only EPR level 2 cmH₂O Humidity level 6 Mask ResMed AirTouch F20 Full Face Mask (large) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 8.0 8.0 8.0 8.0 Epap 8.0 8.0 8.0 8.0 Leak rate 0.0 3.6 4.8 7.2 Resp rate 6.8 17.6 24.8 32.4 Flow limit 0.0 0.0 0.15 0.31 More... Other statistics Time in apnea: 1m 58s (0.37%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirTouch F20 Full Face Mask (large)AHI: 2.930|Leak: 2.073|Pressure: 8.892 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage