August 22
DreamStation Auto CPAP
Francisco’s Account
-
Vitality
98.38Vitality scores AHI Leak rate Usage O2 score Vitality
Top
8.29%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.71
Increased by 1.13
-
Aug 22nd 1.71
Aug 21st 0.58
-
Average Pressure
-
9.5
-
Aug 22nd 9.5
Aug 21st 9.5
-
Average Leak Rate
-
0.63
Increased by 0.35
-
Aug 22nd 0.63
Aug 21st 0.28
-
Daily Usage
-
7h 37m
Increased by 45m
-
Aug 22nd 7h 37m
Aug 21st 6h 52m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Hypopnea 8 1.05 62% Obstructive Apnea 3 0.39 23% Clear Airway Apnea 2 0.26 15% -
Machine Settings
DreamStation Auto CPAP
Machine settings Mode CPAP Pressure 9.5 cmH₂O Mask Philips Respironics DreamWear Gel Nasal Pillow Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 9.5 9.5 9.5 9.5 Epap 9.1 9.3 9.3 9.3 Leak rate 0.0 0.0 6.0 12.0 Resp rate 10.8 13.6 15.4 17.4 More... Other statistics Time in apnea: 0s (0.00%) Large leak: 0s (0.00%) Mask
The mask used on this date
Philips Respironics DreamWear Gel Nasal Pillow Mask (medium)Purchased:8 months agoAHI: 1.539|Leak: 1.018|Pressure: 9.500 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage