September 6
AirCurve11VAuto
Adluso
-
Vitality
100Vitality scores AHI Leak rate Usage O2 score Vitality
Top
0.01%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.32
Decreased by 0.1
-
Sep 6th 0.32
Sep 5th 0.42
-
Average Pressure
-
12.75
Increased by 0.01
-
Sep 6th 12.75
Sep 5th 12.74
-
Average Leak Rate
-
0.11
Decreased by 0.01
-
Sep 6th 0.11
Sep 5th 0.12
-
Daily Usage
-
9h 21m
Decreased by 16m
-
Sep 6th 9h 21m
Sep 5th 9h 37m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Obstructive Apnea 3 0.32 100% -
Machine Settings
AirCurve11VAuto
Machine settings Mode VPAP Auto Mask Full face Min EPAP 8.4 cmH₂O Max IPAP 25.0 cmH₂O PS 3.6 cmH₂O Humidity level 4 Mask ResMed AirFit F20 Full Face Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 12.0 12.62 13.94 15.72 Epap 8.4 9.02 10.34 12.12 Leak rate 0.0 0.0 1.2 3.6 Resp rate 9.4 18.6 27.8 35.2 Flow limit 0.0 0.0 0.01 0.19 More... Other statistics Time in apnea: 34s (0.10%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit F20 Full Face Mask (medium)AHI: 0.584|Leak: 0.316|Pressure: 12.902 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage