August 16, 2024
AirCurve 10 VAuto
Charles’ Account
-
Vitality
97.27Vitality scores AHI Leak rate Usage O2 score Vitality
Top
14.54%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.26
Increased by 0.95
-
Aug 16th 1.26
Aug 15th 0.31
-
Average Pressure
-
16.43
Decreased by 0.21
-
Aug 16th 16.43
Aug 15th 16.64
-
Average Leak Rate
-
10.18
Increased by 1.65
-
Aug 16th 10.18
Aug 15th 8.53
-
Daily Usage
-
8h 43m
Decreased by 4h
-
Aug 16th 8h 43m
Aug 15th 12h 43m
-
-
AHI
Average for 1 night (7 sessions)
.......Events by type Event Count Per hour Share Hypopnea 1 0.11 9% Unidentified Apnea 2 0.23 18% Clear Airway Apnea 8 0.92 73% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Pillows Min EPAP 14.0 cmH₂O Max IPAP 20.0 cmH₂O PS 4.0 cmH₂O Humidity level 4 Ramp pressure 4 cmH₂O Ramp time 20.0 Mask ResMed AirFit F40 Full Face Mask (small wide) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 8.12 18.0 18.46 18.74 Epap 4.12 14.0 14.46 14.74 Leak rate 0.0 0.0 49.2 61.2 Resp rate 6.0 12.4 17.2 21.2 Flow limit 0.0 0.0 0.0 0.22 More... Other statistics Time in apnea: 2m 5s (0.40%) Large leak: 1h 41m 12s (19.35%) Mask
The mask used on this date
ResMed AirFit F40 Full Face Mask (small wide)Purchased:about 1 year agoAHI: 1.290|Leak: 14.788|Pressure: 17.272 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage