Join the fun! Create a free account or sign in

First Day Previous
Next
Last Date
Data recorded in New Delhi (GMT+05:30) time

Vitality

92.84
AHI
100
Leak rate
100
Usage
71.36
O2 score
N/A

Vitality

Top

42.13%

of all users

AHI
Top 0.01% of all users
Leak rate
Top 0.01% of all users
Usage
19.32%
O2 score
N/A

Apnea Hypopnea Index

0.9

Increased by 0.9

Average Pressure

8.0

Average Leak Rate

0.09

Decreased by 1.66

Daily Usage

4h 27m

Increased by 1h 27m

    AHI

    Average for 1 night (3 sessions)

    .......

    Machine Settings

    S9 Lumis VPAP 100 ST

    Mode BiLevel-S
    Mask Full face
    EPAP 6.0 cmH₂O
    IPAP 8.0 cmH₂O
    PS 2.0 cmH₂O
    Mask ResMed AirFit N30 Nasal Mask (medium)
    More...

    Statistics

    Usage Statistics

    Min Med 95% 99.5%
    Pressure 8.0 8.0 8.0 8.0
    Epap 6.0 6.0 6.0 6.0
    Leak rate 0.0 0.0 1.2 2.4
    Resp rate 9.2 15.2 20.6 26.8
    More...
    Time in apnea: 17s (0.11%)
    Large leak: 0s (0.00% )

    Mask

    The mask used on this date

    ResMed AirFit N30 Nasal Mask (medium)
    AHI: 1.631
    |
    Leak: 1.676
    |
    Pressure: 10.157
    Pressure
    Breathing
    Leak Rate
    Flow Limit
    Snore
    SpO2
    Pulse Rate
    Movement
    Sleep Stage

Alert

Sorry, you can only view the most recent 30 days of data on this account.