January 8
AirSense 11 AutoSet
Piko’s Account
-
Vitality
93.95Vitality scores AHI Leak rate Usage O2 score Vitality
Top
35.08%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.66
Decreased by 1.59
-
Jan 8th 1.66
Jan 7th 3.25
-
Average Pressure
-
7.91
Increased by 0.41
-
Jan 8th 7.91
Jan 7th 7.5
-
Average Leak Rate
-
16.16
Increased by 9.62
-
Jan 8th 16.16
Jan 7th 6.54
-
Daily Usage
-
9h 38m
Decreased by 49m
-
Jan 8th 9h 38m
Jan 7th 10h 27m
-
-
AHI
Average for 1 night (6 sessions)
.......Events by type Event Count Per hour Share Hypopnea 2 0.21 13% Obstructive Apnea 4 0.42 25% Clear Airway Apnea 10 1.04 63% -
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 6.0 cmH₂O Pressure Max 8.0 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 6 Mask ResMed AirFit F30i Full Face Mask (wide) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 6.0 8.26 8.88 9.0 Epap 4.0 5.26 5.88 6.0 Leak rate 0.0 10.8 44.4 63.6 Resp rate 4.6 14.2 18.0 23.0 Flow limit 0.0 0.0 0.0 0.17 More... Other statistics Time in apnea: 2m 55s (0.50%) Large leak: 2h 11m 47s (22.80%) Mask
The mask used on this date
ResMed AirFit F30i Full Face Mask (wide)Purchased:9 months agoAHI: 2.016|Leak: 5.461|Pressure: 7.873 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage