February 10
AirSense 11 AutoSet
Stewart’s Account
-
Vitality
99.92Vitality scores AHI Leak rate Usage O2 score Vitality
Top
0.39%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.0
-
Feb 10th 0.0
Feb 9th 0.0
-
Average Pressure
-
10.71
Decreased by 0.25
-
Feb 10th 10.71
Feb 9th 10.96
-
Average Leak Rate
-
0.13
Increased by 0.12
-
Feb 10th 0.13
Feb 9th 0.01
-
Daily Usage
-
6h 58m
Decreased by 1m
-
Feb 10th 6h 58m
Feb 9th 6h 59m
-
-
AHI
Average for 1 night (1 session)
.......No events recorded
-
Machine Settings
AirSense 11 AutoSet
Machine settings Mode APAP Mask Full face Pressure Min 10.6 cmH₂O Pressure Max 13.4 cmH₂O EPR Full time EPR level 3 cmH₂O Humidity level 6 Ramp pressure 9 cmH₂O Ramp time 5.0 Mask ResMed AirFit F40 Full Face Mask (large) — Away More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 9.34 10.6 11.32 12.22 Epap 6.34 7.6 8.32 9.22 Leak rate 0.0 0.0 1.2 3.6 Resp rate 9.6 18.0 20.2 22.2 Flow limit 0.0 0.0 0.0 0.05 More... Other statistics Time in apnea: 0s (0.00%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit F40 Full Face Mask (large)AwayPurchased:11 months agoAHI: 0.523|Leak: 0.266|Pressure: 10.693 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2
No O2 Ring data for this night
-
O2 Ring Pulse Rate
No O2 Ring data for this night
-
O2 Ring Movement
No O2 Ring data for this night
-
Sleep Stage