September 1
AirCurve 11 VAuto
Erik’s Account
-
Vitality
97.42Vitality scores AHI Leak rate Usage O2 score Vitality
Top
13.66%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.13
Increased by 1.27
-
Sep 1st 2.13
Aug 31st 0.86
-
Average Pressure
-
10.0
-
Sep 1st 10.0
Aug 31st 10.0
-
Average Leak Rate
-
1.24
Increased by 0.75
-
Sep 1st 1.24
Aug 31st 0.49
-
Daily Usage
-
8h 26m
Increased by 15m
-
Sep 1st 8h 26m
Aug 31st 8h 11m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Clear Airway Apnea 18 2.13 100% -
Machine Settings
AirCurve 11 VAuto
Machine settings Mode VPAP Auto Mask Pillows Min EPAP 5.0 cmH₂O Max IPAP 10.0 cmH₂O PS 5.0 cmH₂O Humidity level 4 Mask ResMed AirFit P30i Nasal Pillows Mask (large) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 10.0 10.0 10.0 10.0 Epap 5.0 5.0 5.0 5.0 Leak rate 0.0 0.0 7.2 16.8 Resp rate 4.8 12.8 15.0 18.4 Flow limit 0.0 0.0 0.0 0.08 More... Other statistics Time in apnea: 4m 7s (0.81%) Large leak: 2s (0.01%) Mask
The mask used on this date
ResMed AirFit P30i Nasal Pillows Mask (large)AHI: 0.940|Leak: 0.815|Pressure: 10.185 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage