August 27
AirCurve 11 VAuto
Erik’s Account
-
Vitality
99.89Vitality scores AHI Leak rate Usage O2 score Vitality
Top
0.54%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.05
Increased by 0.91
-
Aug 27th 1.05
Aug 26th 0.14
-
Average Pressure
-
10.0
Increased by 1.0
-
Aug 27th 10.0
Aug 26th 9.0
-
Average Leak Rate
-
0.15
Decreased by 2.33
-
Aug 27th 0.15
Aug 26th 2.48
-
Daily Usage
-
9h 33m
Increased by 2h 24m
-
Aug 27th 9h 33m
Aug 26th 7h 9m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Obstructive Apnea 3 0.31 30% Clear Airway Apnea 7 0.73 70% -
Machine Settings
AirCurve 11 VAuto
Machine settings Mode VPAP Auto Mask Pillows Min EPAP 5.0 cmH₂O Max IPAP 10.0 cmH₂O PS 5.0 cmH₂O Humidity level 4 Mask ResMed AirFit P30i Nasal Pillows Mask (large) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 10.0 10.0 10.0 10.0 Epap 5.0 5.0 5.0 5.0 Leak rate 0.0 0.0 0.0 7.2 Resp rate 6.2 12.0 14.6 18.0 Flow limit 0.0 0.0 0.0 0.12 More... Other statistics Time in apnea: 2m 3s (0.36%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit P30i Nasal Pillows Mask (large)AHI: 0.940|Leak: 0.815|Pressure: 10.185 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage