April 16
AirCurve 10 VAuto
Nancy’s Account
-
Vitality
98.8Vitality scores AHI Leak rate Usage O2 score Vitality
Top
6.02%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.23
Increased by 0.23
-
Apr 16th 0.23
Apr 15th 0.0
-
Average Pressure
-
13.0
-
Apr 16th 13.0
Apr 15th 13.0
-
Average Leak Rate
-
0.0
-
Apr 16th 0.0
Apr 15th 0.0
-
Daily Usage
-
8h 37m
Increased by 8m
-
Apr 16th 8h 37m
Apr 15th 8h 29m
-
-
AHI
Average for 1 night (3 sessions)
.......Events by type Event Count Per hour Share Obstructive Apnea 2 0.23 100% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode BiLevel-S Mask Pillows EPAP 4.0 cmH₂O IPAP 13.0 cmH₂O PS 10.0 cmH₂O Humidity level 5 Mask Fisher and Paykel Nova Micro Nasal Pillow Mask (small) — Nova Micro More... -
Statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 13.0 13.0 13.0 13.0 Epap 4.0 4.0 4.0 4.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 7.6 16.4 18.8 22.0 Flow limit 0.0 0.0 0.0 0.0 More... Other statistics Time in apnea: 21s (0.07%) Large leak: 0s (0.00%) Mask
The mask used on this date
Fisher and Paykel Nova Micro Nasal Pillow Mask (small)Nova MicroPurchased:7 months agoAHI: 0.321|Leak: 0.002|Pressure: 13.222 -
Breathing
-
Sleep Stage
-
MovementO2 Ring trimmed to your CPAP session. View full ring session
-
SpO2O2 Ring trimmed to your CPAP session. View full ring session
-
Leak Rate
-
Pulse RateO2 Ring trimmed to your CPAP session. View full ring session
-
Snore
-
Flow Limit
-
Pressure