March 16
AirCurve 10 VAuto
Nancy’s Account
-
Vitality
94.8Vitality scores AHI Leak rate Usage O2 score Vitality
Top
29.66%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.38
Increased by 0.26
-
Mar 16th 0.38
Mar 15th 0.12
-
Average Pressure
-
15.0
-
Mar 16th 15.0
Mar 15th 15.0
-
Average Leak Rate
-
0.0
Decreased by 0.02
-
Mar 16th 0.0
Mar 15th 0.02
-
Daily Usage
-
7h 57m
Decreased by 9m
-
Mar 16th 7h 57m
Mar 15th 8h 6m
-
-
AHI
Average for 1 night (4 sessions)
.......Events by type Event Count Per hour Share Obstructive Apnea 3 0.38 100% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode BiLevel-S Mask Pillows EPAP 7.0 cmH₂O IPAP 15.0 cmH₂O PS 10.0 cmH₂O Humidity level 5 Mask Fisher and Paykel Nova Micro Nasal Pillow Mask (small) — Nova Micro More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 15.0 15.0 15.0 15.0 Epap 7.0 7.0 7.0 7.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 6.2 16.2 19.4 26.0 Flow limit 0.0 0.0 0.0 0.0 More... Other statistics Time in apnea: 1m 14s (0.26%) Large leak: 0s (0.00%) Mask
The mask used on this date
Fisher and Paykel Nova Micro Nasal Pillow Mask (small)Nova MicroPurchased:7 months agoAHI: 0.321|Leak: 0.002|Pressure: 13.222 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2O2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring Pulse RateO2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring MovementO2 Ring trimmed to your CPAP session. View full ring session
-
Sleep Stage