February 14
AirCurve 10 VAuto
Nancy’s Account
-
Vitality
95.4Vitality scores AHI Leak rate Usage O2 score Vitality
Top
25.88%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.24
Increased by 0.24
-
Feb 14th 0.24
Feb 13th 0.0
-
Average Pressure
-
14.0
-
Feb 14th 14.0
Feb 13th 14.0
-
Average Leak Rate
-
0.0
Decreased by 0.09
-
Feb 14th 0.0
Feb 13th 0.09
-
Daily Usage
-
8h 13m
Increased by 34m
-
Feb 14th 8h 13m
Feb 13th 7h 39m
-
-
AHI
Average for 1 night (4 sessions)
.......Events by type Event Count Per hour Share Clear Airway Apnea 2 0.24 100% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode BiLevel-S Mask Pillows EPAP 5.0 cmH₂O IPAP 14.0 cmH₂O PS 10.0 cmH₂O Humidity level 5 Mask Fisher and Paykel Brevida Nasal Pillow Mask (extra small-small (one xs-s seal)) — Brevida More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 14.0 14.0 14.0 14.0 Epap 5.0 5.0 5.0 5.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 8.4 16.2 18.6 21.6 Flow limit 0.0 0.0 0.0 0.0 More... Other statistics Time in apnea: 26s (0.09%) Large leak: 0s (0.00%) Mask
The mask used on this date
Fisher and Paykel Brevida Nasal Pillow Mask (extra small-small (one xs-s seal))BrevidaPurchased:about 1 year agoAHI: 0.702|Leak: 0.077|Pressure: 15.665 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage