January 28
AirCurve 10 VAuto
Nancy’s Account
-
-
Apnea Hypopnea Index
-
0.0
-
Jan 28th 0.0
Jan 27th 0.0
-
Average Pressure
-
NA
-
Average Leak Rate
-
NA
-
Daily Usage
-
7h 22m
Increased by 23m
-
Jan 28th 7h 22m
Jan 27th 6h 59m
-
-
AHI
Average for 1 night (4 sessions)
.......No events recorded
-
Machine Settings
AirCurve 10 VAuto
Machine settings Mode BiLevel-S Mask Full face EPAP 5.0 cmH₂O IPAP 14.0 cmH₂O PS 10.0 cmH₂O Humidity level 4 Mask Fisher and Paykel Brevida Nasal Pillow Mask (extra small-small (one xs-s seal)) — Brevida More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 0.0 0.0 0.0 0.0 Epap 0.0 0.0 0.0 0.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 0.0 0.0 0.0 0.0 Flow limit 0.0 0.0 0.0 0.0 More... Other statistics Time in apnea: 0s (0.00%) Large leak: 0s (0.00%) Mask
The mask used on this date
Fisher and Paykel Brevida Nasal Pillow Mask (extra small-small (one xs-s seal))BrevidaPurchased:about 1 year agoAHI: 0.702|Leak: 0.077|Pressure: 15.665 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2
No O2 Ring data for this night
-
O2 Ring Pulse Rate
No O2 Ring data for this night
-
O2 Ring Movement
No O2 Ring data for this night
-
Sleep Stage