November 15, 2025
AirCurve 10 VAuto
Nancy’s Account
-
Vitality
97Vitality scores AHI Leak rate Usage O2 score Vitality
Top
16.12%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.6
Increased by 0.34
-
Nov 15th 0.6
Nov 14th 0.26
-
Average Pressure
-
15.0
-
Nov 15th 15.0
Nov 14th 15.0
-
Average Leak Rate
-
0.0
-
Nov 15th 0.0
Nov 14th 0.0
-
Daily Usage
-
8h 24m
Increased by 49m
-
Nov 15th 8h 24m
Nov 14th 7h 35m
-
-
AHI
Average for 1 night (4 sessions)
.......Events by type Event Count Per hour Share Clear Airway Apnea 5 0.60 100% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Pillows Min EPAP 5.0 cmH₂O Max IPAP 15.0 cmH₂O PS 10.0 cmH₂O Humidity level 8 Mask Fisher and Paykel Brevida Nasal Pillow Mask (extra small-small (one xs-s seal)) — Brevida More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 15.0 15.0 15.0 15.0 Epap 5.0 5.0 5.0 5.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 8.2 16.6 19.2 21.4 Flow limit 0.0 0.0 0.0 0.02 More... Other statistics Time in apnea: 1m (0.20%) Large leak: 0s (0.00%) Mask
The mask used on this date
Fisher and Paykel Brevida Nasal Pillow Mask (extra small-small (one xs-s seal))BrevidaPurchased:about 1 year agoAHI: 0.702|Leak: 0.077|Pressure: 15.665 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage