June 19, 2025
AirCurve 10 VAuto
Nancy’s Account
-
Vitality
95Vitality scores AHI Leak rate Usage O2 score Vitality
Top
28.39%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.62
Increased by 0.36
-
Jun 19th 0.62
Jun 18th 0.26
-
Average Pressure
-
16.0
-
Jun 19th 16.0
Jun 18th 16.0
-
Average Leak Rate
-
0.0
-
Jun 19th 0.0
Jun 18th 0.0
-
Daily Usage
-
8h 5m
Increased by 18m
-
Jun 19th 8h 5m
Jun 18th 7h 47m
-
-
AHI
Average for 1 night (3 sessions)
.......Events by type Event Count Per hour Share Clear Airway Apnea 5 0.62 100% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Full face Min EPAP 6.6 cmH₂O Max IPAP 16.0 cmH₂O PS 9.4 cmH₂O Humidity level 6 Ramp pressure 7 cmH₂O Ramp time 5.0 Mask ResMed AirTouch N30i Nasal Cushion Mask (small wide) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 16.0 16.0 16.0 16.0 Epap 6.6 6.6 6.6 6.6 Leak rate 0.0 0.0 0.0 0.0 Resp rate 7.6 15.2 17.6 20.4 Flow limit 0.0 0.0 0.0 0.06 More... Other statistics Time in apnea: 1m (0.21%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirTouch N30i Nasal Cushion Mask (small wide)Purchased:almost 2 years agoAHI: 0.563|Leak: 0.033|Pressure: 15.378 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2O2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring Pulse RateO2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring MovementO2 Ring trimmed to your CPAP session. View full ring session
-
Sleep Stage