June 18, 2025
AirCurve 10 VAuto
Nancy’s Account
-
Vitality
99.4Vitality scores AHI Leak rate Usage O2 score Vitality
Top
2.93%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.26
Decreased by 0.36
-
Jun 18th 0.26
Jun 17th 0.62
-
Average Pressure
-
16.0
-
Jun 18th 16.0
Jun 17th 16.0
-
Average Leak Rate
-
0.0
-
Jun 18th 0.0
Jun 17th 0.0
-
Daily Usage
-
7h 47m
Decreased by 14m
-
Jun 18th 7h 47m
Jun 17th 8h 1m
-
-
AHI
Average for 1 night (3 sessions)
.......Events by type Event Count Per hour Share Obstructive Apnea 1 0.13 50% Clear Airway Apnea 1 0.13 50% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Full face Min EPAP 6.6 cmH₂O Max IPAP 16.0 cmH₂O PS 9.4 cmH₂O Humidity level 8 Ramp pressure 7 cmH₂O Ramp time 5.0 Mask ResMed AirFit P30i Nasal Pillows Mask (small) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 16.0 16.0 16.0 16.0 Epap 6.6 6.6 6.6 6.6 Leak rate 0.0 0.0 0.0 0.0 Resp rate 8.2 15.0 17.2 19.6 Flow limit 0.0 0.0 0.0 0.06 More... Other statistics Time in apnea: 32s (0.11%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit P30i Nasal Pillows Mask (small)Purchased:over 1 year agoAHI: 0.547|Leak: 0.014|Pressure: 15.715 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage