May 31, 2025
AirCurve 10 VAuto
Nancy’s Account
-
Vitality
99Vitality scores AHI Leak rate Usage O2 score Vitality
Top
4.98%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.12
Decreased by 0.61
-
May 31st 0.12
May 30th 0.73
-
Average Pressure
-
15.0
-
May 31st 15.0
May 30th 15.0
-
Average Leak Rate
-
0.0
-
May 31st 0.0
May 30th 0.0
-
Daily Usage
-
8h 7m
Decreased by 9m
-
May 31st 8h 7m
May 30th 8h 16m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Clear Airway Apnea 1 0.12 100% -
Machine Settings
AirCurve 10 VAuto
Machine settings Mode VPAP Auto Mask Full face Min EPAP 7.0 cmH₂O Max IPAP 15.0 cmH₂O PS 8.0 cmH₂O Humidity level 8 Ramp pressure 7 cmH₂O Ramp time 5.0 Mask No mask More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 15.0 15.0 15.0 15.0 Epap 7.0 7.0 7.0 7.0 Leak rate 0.0 0.0 0.0 0.0 Resp rate 8.4 15.6 17.8 20.6 Flow limit 0.0 0.0 0.0 0.05 More... Other statistics Time in apnea: 10s (0.03%) Large leak: 0s (0.00%) Mask
The mask used on this date
No mask was set on this date
-
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring trimmed to your CPAP session. View full ring session
-
O2 Ring trimmed to your CPAP session. View full ring session
-
Sleep Stage