August 11
AirSense 10 AutoSet
Abdulla’s Account
-
Vitality
99.53Vitality scores AHI Leak rate Usage O2 score Vitality
Top
2.27%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
0.88
Increased by 0.04
-
Aug 11th 0.88
Aug 10th 0.84
-
Average Pressure
-
13.36
Increased by 0.04
-
Aug 11th 13.36
Aug 10th 13.32
-
Average Leak Rate
-
2.24
Decreased by 8.5
-
Aug 11th 2.24
Aug 10th 10.74
-
Daily Usage
-
6h 49m
Increased by 53m
-
Aug 11th 6h 49m
Aug 10th 5h 56m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Obstructive Apnea 5 0.73 83% Clear Airway Apnea 1 0.15 17% -
Machine Settings
AirSense 10 AutoSet
Machine settings Mode VPAP Auto Mask Full face Min EPAP 9.0 cmH₂O Max IPAP 15.0 cmH₂O PS 4.0 cmH₂O Humidity level 6 Mask ResMed AirTouch F20 Full Face Mask (large) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 13.0 13.32 13.84 14.1 Epap 9.0 9.32 9.84 10.1 Leak rate 0.0 0.0 12.0 31.2 Resp rate 8.2 17.4 20.4 27.2 Flow limit 0.0 0.0 0.0 0.08 More... Other statistics Time in apnea: 1m 16s (0.31%) Large leak: 7m 52s (1.92%) Mask
The mask used on this date
ResMed AirTouch F20 Full Face Mask (large)AHI: 1.218|Leak: 3.498|Pressure: 15.458 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage