December 10, 2025
AirCurve 11 VAuto
Abdulla’s Account
-
Vitality
93.91Vitality scores AHI Leak rate Usage O2 score Vitality
Top
35.29%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.38
Increased by 0.7
-
Dec 10th 1.38
Dec 8th 0.68
-
Average Pressure
-
16.0
Increased by 0.07
-
Dec 10th 16.0
Dec 8th 15.93
-
Average Leak Rate
-
0.63
Decreased by 0.22
-
Dec 10th 0.63
Dec 8th 0.85
-
Daily Usage
-
5h 5m
Increased by 2h 8m
-
Dec 10th 5h 5m
Dec 8th 2h 57m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 1 0.20 14% Obstructive Apnea 6 1.18 86% -
Machine Settings
AirCurve 11 VAuto
Machine settings Mode Unknown Mask Full face Min EPAP 12.0 cmH₂O Max IPAP 16.0 cmH₂O PS 4.0 cmH₂O Humidity level 5 Mask ResMed AirFit X30i Full Face Mask (large) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 16.0 16.0 16.0 16.0 Epap 12.0 12.0 12.0 12.0 Leak rate 0.0 0.0 6.0 8.4 Resp rate 8.6 16.4 21.0 29.0 Flow limit 0.0 0.0 0.01 0.17 More... Other statistics Time in apnea: 1m 16s (0.42%) Large leak: 0s (0.00%) Mask
The mask used on this date
ResMed AirFit X30i Full Face Mask (large)AHI: 1.191|Leak: 3.387|Pressure: 15.259 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage