March 13
AirCurve 11 VAuto
Abdulla’s Account
-
Vitality
95.02Vitality scores AHI Leak rate Usage O2 score Vitality
Top
28.24%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
2.55
Decreased by 7.65
-
Mar 13th 2.55
Mar 12th 10.2
-
Average Pressure
-
15.5
Decreased by 1.07
-
Mar 13th 15.5
Mar 12th 16.57
-
Average Leak Rate
-
8.4
Increased by 4.02
-
Mar 13th 8.4
Mar 12th 4.38
-
Daily Usage
-
8h 38m
Increased by 2h 51m
-
Mar 13th 8h 38m
Mar 12th 5h 47m
-
-
AHI
Average for 1 night (10 sessions)
.......Events by type Event Count Per hour Share Hypopnea 3 0.35 14% Obstructive Apnea 11 1.27 50% Clear Airway Apnea 8 0.93 36% -
Machine Settings
AirCurve 11 VAuto
Machine settings Mode Unknown Mask Full face Min EPAP 11.0 cmH₂O Max IPAP 17.0 cmH₂O PS 4.0 cmH₂O Humidity level 5 Mask ResMed AirFit P30i Nasal Pillows Mask (large) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 12.0 15.68 17.0 18.0 Epap 8.0 11.68 12.0 12.26 Leak rate 0.0 0.0 46.8 102.0 Resp rate 5.0 16.0 19.8 29.6 Flow limit 0.0 0.0 0.0 0.16 More... Other statistics Time in apnea: 4m 21s (0.84%) Large leak: 31m 23s (6.06%) Mask
The mask used on this date
ResMed AirFit P30i Nasal Pillows Mask (large)AHI: 1.556|Leak: 3.386|Pressure: 14.602 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2Custom scale Data above scale Data below scale
-
O2 Ring Pulse RateCustom scale Data above scale Data below scale
-
O2 Ring MovementCustom scale Data above scale Data below scale
-
Sleep Stage