March 5
AirCurve 11 VAuto
Abdulla’s Account
-
Vitality
98.62Vitality scores AHI Leak rate Usage O2 score Vitality
Top
6.96%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
1.6
Decreased by 0.33
-
Mar 5th 1.6
Mar 4th 1.93
-
Average Pressure
-
14.16
Decreased by 1.84
-
Mar 5th 14.16
Mar 4th 16.0
-
Average Leak Rate
-
2.02
Increased by 1.81
-
Mar 5th 2.02
Mar 4th 0.21
-
Daily Usage
-
7h 31m
Decreased by 1h 48m
-
Mar 5th 7h 31m
Mar 4th 9h 19m
-
-
AHI
Average for 1 night (2 sessions)
.......Events by type Event Count Per hour Share Obstructive Apnea 5 0.67 42% Clear Airway Apnea 7 0.93 58% -
Machine Settings
AirCurve 11 VAuto
Machine settings Mode Unknown Mask Full face Min EPAP 10.4 cmH₂O Max IPAP 14.4 cmH₂O PS 3.6 cmH₂O Humidity level 5 Mask ResMed AirFit P30i Nasal Pillows Mask (large) More... -
Statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 14.0 14.14 14.36 14.4 Epap 10.4 10.54 10.76 10.8 Leak rate 0.0 0.0 9.6 43.2 Resp rate 7.2 17.0 20.2 27.8 Flow limit 0.0 0.0 0.0 0.12 More... Other statistics Time in apnea: 2m 30s (0.55%) Large leak: 7m 56s (1.76%) Mask
The mask used on this date
ResMed AirFit P30i Nasal Pillows Mask (large)AHI: 1.556|Leak: 3.386|Pressure: 14.602 -
Pressure
-
Breathing
-
Leak Rate
-
Flow Limit
-
Snore
-
SpO2
-
Pulse Rate
-
Movement
-
Sleep Stage