April 22
AirSense 10 AutoSet
Henry’s Account
-
Vitality
79.37Vitality scores AHI Leak rate Usage O2 score Vitality
Bottom
4.61%of all users
Vitality percentile rankings AHI Leak rate Usage O2 score -
-
Apnea Hypopnea Index
-
5.1
Increased by 1.38
-
Apr 22nd 5.1
Apr 21st 3.72
-
Average Pressure
-
9.66
Decreased by 0.08
-
Apr 22nd 9.66
Apr 21st 9.74
-
Average Leak Rate
-
7.06
Increased by 0.63
-
Apr 22nd 7.06
Apr 21st 6.43
-
Daily Usage
-
3h 20m
Decreased by 2h 19m
-
Apr 22nd 3h 20m
Apr 21st 5h 39m
-
-
AHI
Average for 1 night (1 session)
.......Events by type Event Count Per hour Share Hypopnea 12 3.60 71% Unidentified Apnea 5 1.50 29% -
Machine Settings
AirSense 10 AutoSet
Machine settings Mode ASV Mask Nasal EPAP 8.0 cmH₂O Max IPAP 14.0 cmH₂O Humidity level 5 Mask ResMed AirFit™ N20 Nasal Mask (medium) More... -
CPAP statistics
Usage Statistics
Usage statistics by percentile Metric Min Med 95% 99.5% Pressure 8.0 8.56 14.0 14.0 Epap 8.0 8.0 8.0 8.0 Leak rate 0.0 0.0 31.2 39.6 Resp rate 2.8 13.6 15.2 16.4 Flow limit 0.0 0.0 0.0 0.39 More... Other statistics Time in apnea: 1m 7s (0.56%) Large leak: 26m 42s (13.35%) Mask
The mask used on this date
ResMed AirFit™ N20 Nasal Mask (medium)Purchased:8 months agoAHI: 3.018|Leak: 3.751|Pressure: 9.929 -
PressureCustom scale Data above scale Data below scale
-
BreathingCustom scale Data above scale Data below scale
-
Leak RateCustom scale Data above scale Data below scale
-
Flow LimitCustom scale Data above scale Data below scale
-
SnoreCustom scale Data above scale Data below scale
-
O2 Ring SpO2
No O2 Ring data for this night
-
O2 Ring Pulse Rate
No O2 Ring data for this night
-
O2 Ring Movement
No O2 Ring data for this night
-
Sleep Stage