Join the fun! Create a free account or sign in

Magic Uploader Xtreme Launch Special

To celebrate the launch of the Magic Uploader Xtreme, get a year of SleepHQ Pro for only $119 USD (normally $149 USD).

Offer ends in 9 days.

Machine
Data recorded in Eastern Time (US & Canada) (GMT-04:00) time
  • Vitality

    81.14
    Vitality scores
    AHI
    86.05
    Leak rate
    100
    Usage
    52.46
    O2 score
    N/A

    Vitality

    Bottom

    7.32%

    of all users

    Vitality percentile rankings
    AHI
    Bottom 32.39%
    Leak rate
    Top 0.01% of all users
    Usage
    2.16%
    O2 score
    N/A
  • Apnea Hypopnea Index

    4.24

    Increased by 0.33

    Average Pressure

    11.31

    Decreased by 1.07

    Average Leak Rate

    0.08

    Increased by 0.05

    Daily Usage

    3h 4m

    Decreased by 31m

  • AHI

    Average for 1 night (2 sessions)

    .......
  • Machine Settings

    AirSense 10 AutoSet

    Machine settings
    Mode ASV
    Mask Full face
    EPAP 7.0 cmH₂O
    Max IPAP 15.0 cmH₂O
    Humidity level 5
    Mask Löwenstein Medical LENA Full Face Mask (medium) — Lena
    More...
  • CPAP statistics

    Usage Statistics

    Usage statistics by percentile
    Metric Min Med 95% 99.5%
    Pressure 7.0 10.06 15.0 15.0
    Epap 7.0 7.0 7.0 7.0
    Leak rate 0.0 0.0 0.0 2.4
    Resp rate 3.6 13.0 15.8 17.6
    Flow limit 0.0 0.0 0.0 1.0
    More...
    Other statistics
    Time in apnea: 1m 44s (0.94%)
    Large leak: 10s (0.09%)

    Mask

    The mask used on this date

    Löwenstein Medical LENA Full Face Mask (medium)
    Lena
    Purchased:
    8 months ago
    AHI: 3.210
    |
    Leak: 1.073
    |
    Pressure: 11.074
  • Pressure
  • Breathing
  • Leak Rate
  • Flow Limit
  • Snore
  • O2 Ring SpO2

    No O2 Ring data for this night

  • O2 Ring Pulse Rate

    No O2 Ring data for this night

  • O2 Ring Movement

    No O2 Ring data for this night

  • Sleep Stage