Join the fun! Create a free account or sign in

Data recorded in Eastern Time (US & Canada) (GMT-04:00) time

Vitality

86.12
AHI
78.8
Leak rate
86.87
Usage
100
O2 score
N/A

Vitality

Bottom

21.62%

of all users

AHI
11.09%
Leak rate
29.46%
Usage
Top 0.01% of all users
O2 score
N/A

Apnea Hypopnea Index

6.16

Decreased by 0.85

Average Pressure

8.64

Decreased by 0.02

Average Leak Rate

13.18

Increased by 1.43

Daily Usage

7h 57m

by

    AHI

    Average for 1 night (1 session)

    .......

    Machine Settings

    AirSense 11 AutoSet

    Mode APAP
    Mask Pillows
    Pressure Min 7.0 cmH₂O
    Pressure Max 10.0 cmH₂O
    EPR Full time
    EPR level 1 cmH₂O
    Humidity level 5
    Ramp pressure 5 cmH₂O
    Ramp time 20.0
    Mask ResMed AirFit F40 (F40)
    More...

    Statistics

    Usage Statistics

    Min Med 95% 99.5%
    Pressure 5.06 8.76 9.84 10.0
    Epap 4.06 7.76 8.84 9.0
    Leak rate 0.0 12.0 30.0 48.0
    Resp rate 2.8 14.2 18.4 33.6
    Flow limit 0.0 0.0 0.03 0.29
    More...
    Time in apnea: 11m 11s (2.34%)
    Large leak: 1h 5m 16s (13.68% )

    Mask

    The mask used on this date

    ResMed AirFit F40 Full Face Mask (medium)
    F40
    Purchased:
    20 days ago
    AHI: 4.902
    |
    Leak: 11.925
    |
    Pressure: 8.428
    Pressure
    Breathing
    Leak Rate
    Flow Limit
    Snore
    SpO2
    Pulse Rate
    Movement
    Sleep Stage